en
 

SSBD DIGITAL LOAD CELL

1000kg. 2000kg. 5000kg. 10000kg.

The SSBD shear beam digital load cell has been developed for use in electronic weight and force measurement applications under industrial conditions. The precise and rugged SSBD digital load cell offers high resistance to side forces and overload conditions.

The stainless steel SSBD shear beam digital load cell can be used under the most severe industrial conditions. With a fully welded strain gauge area, SSBD is protected to IP68 standards and is resistant to water and other chemicals.

The SSBD digital load cell has faults and warning flags to notify its status to devices connected to the load cell. Therefore, the master devices can detect the normal operation of the loadcell and take the necessary precautions for fault situations.

The product finds application in :

• Medium capacity platform scales
• Tank weighing systems
• Automatic weighing equipment
• Process weighing applications in industries like:
- Construction;
- Food;
- Chemicals;
- Petrochemicals;
- Caustic Soda;
- Fertilizers.

Features:

  • Stainless Steel

  • Easy-to-mount

  • Certified to OIML R60 standards

  • Hermetic-sealed strain gauge area

  • Resistant to side forces

  • Heavy duty

  • IP68 industrial protection

  • Installation angle compensation

  • CANBUS / RS485 communication

  • Measurement error and faulty detection

  • 24-bit A/D converter

Technical specification:

Model

Capacities

Minimum Division

Maximum Overload Capacity

SSBD 1000

1000 kg

21 g

1500 kg

SSBD 2000

2000 kg

42 g

3000 kg

SSBD 5000

5000 kg

105 g

7500 kg

SSBD 10000

10000 kg

210 g

15000 kg

Specifications:

Maximum capacities (Emax) kg 1000*, 2000, 5000, 10000
Accuracy (OIML R60) C3                C6                   C3
Maximum number of verification intervals (n ) 3000          6000           10000
Minimum verification interval (V ) Emax/20000 Emax/30000 Emax/47619
Combined error % ≤ ±0.04, ≤ ±0.02 ≤ ±0.012
Creep error over 30 min. (DR) %Emax ≤ ±0.0035≤ ±0.0035 ≤±0.0035
Maximum safe overload %Emax 150
Maximum safe sideload %Emax 100
Ultimate load %Emax 300
Stretching (Emax) mm ≤0.5
Excitation voltage (Umax) V 12-24 DC
Output signal (at nominal load) Count 200000
Analog/Digital converter (sigma delta)  Bit 24
Analog/Digital converter speed  Hz 6 to 800 configurable
Asynchronous communication speed  Baud CANOpen 500kbps, Modbus 115.200 kbps
Data interface CANOpen or Modbus
Angle measurement error Градус 0.1
Insulation voltage  V 2500
Compensated temperature range  °C -10…+40
Operating temperature range   °C -40…+70
Load cell material Stainless Steel
Sealing (EN60529) IP68
Weight  kg 2.1 – 4.2 – 7.56
Package dimensions / weight    cm/kg 1x33x8.5 – 24x41x9 / 2.2 – 4.3 – 8.1