LCA-D LOAD CELL TRANSMITTER
LCA-D load cell amplifiers weigh various tanks and similar units and enable remote monitoring of all measurements in the most cost-effective way possible. Weights of one or more unit’s being weighed by the load cells can either be viewed on the LCA-D devices, which are mounted next to the weighing system, and they can also be monitored via a remote computer. LCA-D distinguishes itself by enabling computerized setup of all parameters through the Modbus communication protocol.
This enables monitoring and programming of several LCAs, which are connected to the same communication bus, from a single control point such as a PC or a PLC. Two Windows TM-based software programs have been developed for communication with the LCA devices. The first one, Dlms_VP (Digital Load Cell Measurement System Virtual Panel) can communicate with only one LCA device and setting up all parameters remotely. The second, Dlms_NW (Digital Load Cell Measurement System Network), gives way to viewing more than one LCA amplifiers at the same time. The aluminium cast housing makes the device serviceable even under dusty, humid and corrosive conditions.

Features;
-
Dust and moisture resistant, aluminium cast housing
-
Illuminated LCD display
-
Dust and humidity-proof membrane type keyboard
-
Taring, zeroing, function and adjustment keys
-
Zeroing within the entire measurement range
-
Gain adjustment for load cell output
-
Digital linearization
-
Digital temperature compensation
-
Remote access to all internal parameters (Modbus)
-
RS232 / RS485 serial output
Options:
| Category | Specification |
| Accuracy | |
| Accuracy class (OIML approved) | 7000d (III) |
| Input sensitivity | 0.5µV/digit |
| Sensitivity | %0.003 |
| Zero and gain stability | 3.6ppm/°C |
| A/D converter | 24-bit Sigma-Delta |
| Digital filter | Adjustable numerical filtering |
| Reading frequency | 50Hz |
| Loadcell | |
| Number of Loadcells allowed | 8 pieces (350Ω) |
| Analog input range | ± 160mV/V |
| Excitation voltage | 10V DC |
| Environment | |
| Operating temperature range (OIML approved) | -10°C to +40°C |
| Storage temperature range | -20°C to +70°C |
| Operating voltage and power | 10-35V DC, 5W |
| Operator handling and Display | |
| Keyboard | Dust and humidity-proof membrane keyboard with 3 tact keys |
| Weight display | 4.5 mm, 40-pixel, green LCD, 2x16 digit |
| Function display | - |
| Program Indicator | - |
| Housing | |
| Material and protection class | Aluminium, IP66 |
| Weight | 1kg |
| Package weight and dimensions | 1.1kg, 15x24x6cm |
| Communication | Standard Optional |
| Serial communication output | RS232 / RS485 - |
| Parallel printer output | - - |
| Binary (BCD) output | - - |
| Remote display output | - - |
| Digital input / output | - 2 output (250V/2A relay) |
| Analog output | - 4-20mA |
Areas of Use
-
Tanks Weighing Systems
-
Overload Control Systems
-
Chemistry & Petrochemistry